M2VT-C1-R2/K
AI

The **M2VT-C1-R2/K** is a high-performance, signal-conditioning plug-in transducer, typically manufactured by **M-System**. It is specifically designed to convert a standard DC input into two isolated DC output signals.
---
### 1. Technical Specifications
The model code breaks down into specific electronic characteristics:
| Code Segment | Description | Details |
| :--- | :--- | :--- |
| **M2VT** | Model Series | V-Unit Signal Conditioner (Isolator) |
| **C1** | Input Type | 1 – 5V DC |
| **R2** | Output 1 & 2 | 4 – 20mA DC (Dual Output) |
| **K** | Power Supply | 85 – 132V AC |
### 2. Key Electronic Components & Internal Architecture
The device utilizes several core electronic principles to ensure signal integrity:
* **Galvanic Isolation:** The device provides 3-way isolation between the **input**, **output**, and **power supply**. This protects sensitive PLC/DCS systems from ground loops and high-voltage surges.
* **Operational Amplifiers (Op-Amps):** Used for precise signal scaling and impedance matching to ensure the 1-5V input is accurately reflected in the 4-20mA output.
* **A/D and D/A Conversion:** Modern versions often use high-resolution converters to maintain linearity (typically $\pm0.1\%$) and temperature stability.
* **Zero/Span Adjustments:** Located on the front panel, these potentiometers allow for fine-tuning the calibration of the electronic circuit.
### 3. Wiring Configuration
To integrate this part into a circuit, the following terminal mapping is generally used:
```markdown
Terminal | Function
---------|----------
1 | Output 1 (+)
2 | Output 1 (-)
3 | Output 2 (+)
4 | Output 2 (-)
5 | Input (+)
6 | Input (-)
7 | Power (L)
8 | Power (N)
```
### 4. Application Context
* **Signal Splitting:** It takes one process variable (like pressure or temperature) and provides two identical signals for a controller and a local display simultaneously.
* **Noise Filtering:** The internal electronics filter out high-frequency electromagnetic interference (EMI) often found in industrial environments.
---
- ⤷What is the maximum isolation voltage for the M2VT series?
- ⤷ How do I calibrate the Zero and Span on this specific model?
- ⤷ Can the output be changed from current to voltage in the field?