  VI-2VT2-CU Datasheet HTML 1Page - Vicor Corporation VI-2VT2-CU Datasheet HTML 2Page - Vicor Corporation VI-2VT2-CU Datasheet HTML 3Page - Vicor Corporation VI-2VT2-CU Datasheet HTML 4Page - Vicor Corporation VI-2VT2-CU Datasheet HTML 5Page - Vicor Corporation VI-2VT2-CU Datasheet HTML 6Page - Vicor Corporation VI-2VT2-CU Datasheet HTML 7Page - Vicor Corporation  
Zoom Inzoom in Zoom Outzoom out
 3 / 7 page
background image
VI-200 DC-DC Converters
Rev 3.9
Page 3 of 7
08/2017
VI-200, VE-200
Converter Specifications (Cont.)
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
[a] 10V to 15V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
3.3V output trim range 2.20 to 3.63V, 95V output –50 + 0% trim range.
[b] 131% nominal for booster modules.
[c] Output voltages of 3.3V or 5V incorporate foldback current limiting; For output voltages from 5.2V to 7.5V consult factory;
All other outputs provide constant current limiting.
Output Characteristics
Control Pin Specifications
VI-200 E-Grade
VI-200 C-, I-, M-Grade
Parameter
Min
Typ
Max
Min
Typ
Max
Units
Test
Conditions
Setpoint accuracy
1%
2%
0.5%
1%
VNOM
Load/line
regulation
0.5%
0.05%
0.2%
VNOM
LL to HL, 10%
to Full Load
Load/line
regulation
1%
0.2%
0.5%
VNOM
LL to HL, No
Load to 10%
Output
temperature drift
0.02
0.01
0.02
% / °C
Over rated
temp.
Long term drift
0.02
0.02
%/1K hours
Output ripple – pp:
150
60
100
mV
20MHz
bandwidth
2V, 3.3V
5V
5%
2%
3%
VNOM
20MHz
bandwidth
10 – 95V
3%
0.75%
1.5%
VNOM
20MHz
bandwidth
Trim range [a]
50%
110%
50%
110%
VNOM
Total
remote sense
compensation
0.5
0.5
Volts
0.25V max.
neg. leg
OVP set point
125% [b]
115%
125% [b]
135%
VNOM
Recycle power
Current limit
105%
135%
105%
125%
IFULL LOAD
Automatic
restart
Short circuit
current [c]
20%
140%
20%
130%
IFULL LOAD
Automatic
restart
VI-200 E-Grade
VI-200 C-, I-, M-Grade
Parameter
Min
Typ
Max
Min
Typ
Max
Units
Test
Conditions
Gate out
impedance
50
50
Ohms
Gate in impedance
1000
1000
Ohms
Gate in open
circuit voltage
6
6
Volts
Use open
collector
Gate in low
threshold
0.65
0.65
Volts
Gate in low
current
6
6
mA
Power sharing
accuracy
0.95
1.05
0.95
1.05
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 5.



Html Pages

1 2 3 4 5 6 7


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com