  43AL1-S/Q Datasheet HTML 1Page - M-System Co.,Ltd. 43AL1-S/Q Datasheet HTML 2Page - M-System Co.,Ltd. 43AL1-S/Q Datasheet HTML 3Page - M-System Co.,Ltd. 43AL1-S/Q Datasheet HTML 4Page - M-System Co.,Ltd. 43AL1-S/Q Datasheet HTML 5Page - M-System Co.,Ltd. 43AL1-S/Q Datasheet HTML 6Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 2 / 6 page
background image
MODEL: 43AL1
43AL1 SPECIFICATIONS
ES-9425 Rev.9 Page 2/6
https://www.m-system.co.jp/
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Panel flush mounting
Weight: 30 g (1.1 oz)
PERFORMANCE
Accuracy: ±0.1 % rdg ±1 digit× scaling-multiple
(When the scaling-multiple is less than 1, rounded up to 1.)
Temp. coefficient: ±0.3 digits× scaling-multiple/℃
(When the scaling-multiple is less than 1, rounded up to 1.)
Scaling-multiple = | (Display Scaling Value B - Display
Scaling Value A) ÷ (default Display Scaling Value B - default
Display Scaling Value A) |
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 500 V AC @1 minute (input to FE)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
Approval:
UL/C-UL general safety requirements
(UL 61010-1, CAN/CSA-C22.2 No.61010-1-12)
EXTERNAL VIEW
(1) Front Cover
(2) 4-digit Display
(6) UP Button
(5) SF Button
(3) DI Button
(4) SC Button
■ COMPONENT IDENTIFICATION
No.
COMPONENT
FUNCTIONS
(1)
Front Cover
Removed at conguration.
(2)
4-digit Display
4-digit LED display. Range: -1999 to 9999 (not including decimal point)
(3)
DI Button
Used to move on to the display setting modes; or to shift through setting items in each setting
mode.
(4)
SC Button
Used to move on to the scaling setting modes; or to shift through setting items in each setting
mode.
(5)
SF Button
Used to move on to the setting standby status and shift through display digits in each setting
item.
(6)
UP Button
Used to select setting value.



Html Pages

1 2 3 4 5 6


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com