11 / 20 page ![]() AD539 Rev. B | Page 11 of 20 The power supplies to the AD539 can be as low as ±4.5 V and as high as ±16.5 V. The maximum allowable range of the signal inputs, VY, is approximately 0.5 V above +VS; the minimum value is 2.5 V above −VS. To accommodate the peak specified inputs of ±4.2 V the supplies should be nominally +5 V and −7.5 V. Although there is no performance advantage in raising supplies above these values, it may often be convenient to use the same supplies as for the op amps. The AD539 can tolerate the excess voltage with only a slight effect on dc accuracy but dissipation at ±16.5 V can be as high as 535 mW, and some form of heat sink is essential in the interests of reliability. TRANSFER FUNCTION In using any analog multiplier or divider, careful attention must be paid to the matter of scaling, particularly in computational applications. To be dimensionally consistent, a scaling voltage must appear in the transfer function, which, for each channel of the AD539 in the standard multiplier configuration (see Figure 20), is VW = −VXVY/VU where the VX and VY inputs, the VW output, and the scaling voltage, VU, are expressed in a consistent unit, usually volts. In this case, VU is fixed by the design to be 1 V and it is often acceptable in the interest of simplification to use the less rigorous expression VW = −VXVY where it is understood that all signals must be expressed in volts, that is, they are rendered dimensionless by division by 1 V. The accuracy specifications for VU allow the use of either of the two feedback resistors supplied with each channel, because these are very closely matched, or they can be used in parallel to halve the gain (double the effective scaling voltage), when VW = −VXVY/2 When an external load resistor, RL, is used, the scaling is no longer exact because the internal thin film resistors, although trimmed to high ratiometric accuracy, have an absolute tolerance of 20%. However, the nominal transfer function is VW = −VXVY/VU’ where the effective scaling voltage, VU’, can be calculated for each channel using the formula VU’ = VU (5RL + 6.25)/RL where RL is expressed in kilohms. For example, when RL = 100 Ω, VU’ = 67.5 V. Table 5 provides more detailed data for the case where both channels are used in parallel. The AD539 can also be used with no external load (CHAN2 OUTPUT, Pin 11, or CHAN1 OUTPUT, Pin 14, open circuit), when VU’ is precisely 5 V. DUAL SIGNAL CHANNELS The signal voltage inputs, VY1 and VY2, have nominal full-scale (FS) values of ±2 V with a peak range to ±4.2 V (using a negative supply of 7.5 V or greater). For video applications where differential phase is critical, a reduced input range of ±1 V is recommended, resulting in a phase variation of typically ±0.2° at 3.579 MHz for full gain. The input impedance is typically 400 kΩ shunted by 3 pF. Signal channel distortion is typically well under 0.1% at 10 kHz and can be reduced to 0.01% by using the channels differentially. COMMON CONTROL CHANNEL The control channel accepts positive inputs, VX, from 0 V to 3 V FS, ±3.3 V peak. The input resistance is 500 Ω. An external, grounded capacitor determines the small-signal bandwidth and recovery time of the control amplifier; the minimum value of 3 nF allows a bandwidth at midgain of about 5 MHz. Larger compensation capacitors slow the control channel but improve the high frequency performance of the signal channels. FLEXIBLE SCALING Using either one or two external op amps in conjunction with the on-chip 6 kΩ scaling resistors (see Figure 19), the output currents (nominally ±1 mA FS, ±2.25 mA peak) can be converted to voltages with accurate transfer functions of VW = −VXVY/2, VW = −VXVY, or VW = −2VXVY (where the VX and VY inputs and VW output are expressed in volts), with correspond- ing full-scale outputs of ±3 V, ±6 V, and ±12 V. Alternatively, low impedance grounded loads can be used to achieve the full signal bandwidth of 60 MHz, in which mode the scaling is less accurate. VX VY1 W1 VW1 = –VXVY1 VW2 = –VXVY2 Z1 EXTRNAL OP AMPS VY2 Z2 W2 CHAN1 MULTIPLY CHAN2 MULTIPLY – – Figure 19. Block Diagram Showing Scaling Resistors and External Op Amps |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |