Back Button CM-MSS.23P Datasheet HTML 5Page - ABB CM-MSS.23P Datasheet HTML 6Page - ABB CM-MSS.23P Datasheet HTML 7Page - ABB CM-MSS.23P Datasheet HTML 8Page - ABB CM-MSS.23P Datasheet HTML 9Page - ABB CM-MSS.23P Datasheet HTML 10Page - ABB CM-MSS.23P Datasheet HTML 11Page - ABB CM-MSS.23P Datasheet HTML 12Page - ABB CM-MSS.23P Datasheet HTML 13Page - ABB  
Zoom Inzoom in Zoom Outzoom out
 9 / 13 page
background image
Data sheet | Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 - 9
Environmental data
Ambient temperature ranges
operation -25...+60 °C (-13...+140 °F)
storage -40...+85 °C (-40...+185 °F)
Damp heat, cyclic (IEC/EN 60068-2-30)
6 x 24 h cycle, 55 °C, 95 % RH
Climatic class (IEC/EN 60721-3-3)
3K5 (no condensation, no ice formation)
Vibration, sinusoidal
5-13.2 Hz: w1 mm; 13.2-100 Hz: 0.7 g
Shock
10 g / 11 ms
Isolation data
CM-MSS.22
CM-MSS.23
Rated insulation voltage Ui
Supply circuit / Measuring circuit1) n/a
300 V AC
Supply circuit / Output circuits 300 V AC
Measuring circuit1) / Output circuits 300 V AC
Output circuit 1 / Output circuit 2 300 V AC
Rated impulse withstand voltage Uimp
Supply circuit / Measuring circuit1) n/a
4 kV
Supply circuit / Output circuits 4 kV
Measuring circuit1) / Output circuits 4 kV
Output circuit 1 / Output circuit 2 4 kV
Basic insulation
Supply circuit / Measuring circuit1) n/a
600 V AC
Supply circuit / Output circuits 600 V AC
Measuring circuit1) / Output circuits 600 V AC
Output circuit 1 / Output circuit 2 300 V AC
Protective separation
(IEC/EN 61140, EN 50178)
Supply circuit / Measuring circuit1) no
yes, up to 300 V
Supply circuit / Output circuits yes
Measuring circuit1) / Output circuits yes
Output circuit 1 / Output circuit 2 no
Pollution degree
3
Overvoltage category
III
1)
Potential of measuring circuit = potential of control circuit
Standards / Directives
Standards
IEC/EN 60947-5-1, IEC/EN 60947-8
Low Voltage Directive
2014/35/EU
EMC Directive
2014/30/EU
RoHS Directive
2011/65/EU



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com