21 / 54 page ![]() CS5460A DS487F4 21 3. FUNCTIONAL DESCRIPTION 3.1 Pulse-Rate Output As an alternative to reading the real energy through the serial port, the EOUT and EDIR pins provide a simple interface with which signed ener- gy can be accumulated. Each EOUT pulse repre- sents a predetermined quantity of energy. The quantity of energy represented in one pulse can be varied by adjusting the value in the Pulse-Rate Register. Corresponding pulses on the EDIR out- put pin signify that the sign of the energy is nega- tive. Note that these pulses are not influenced by the value of the Cycle-Count Register, and they have no reliance on the computation cycle, de- scribed earlier. With MCLK = 4.096 MHz, K = 1, the pulses will have an average frequency (in Hz) equal to the frequency setting in the Pulse Rate Register when the input signals into the voltage and current channels cause full-scale readings in the Instantaneous Voltage and Current Registers. When MCLK/K is not equal to 4.096 MHz, the pulse-rate should be scaled by a factor of 4.096 MHz / (MCLK/K) to get the actual output pulse-rate. EXAMPLE #1: For a power line with maximum rat- ed levels of 250 V (RMS) and 20 A (RMS), the pulse-frequency on the EOUT pin needs to be ‘IR’ = 100 pulses-per-second (100 Hz) when the RMS-voltage and RMS-current levels on the power line are 220 V and 15 A respectively. To meet this requirement, the pulse-rate frequency (‘PR’) in the Pulse-Rate Register must be set accordingly. After calibration, the first step to finding the value of ‘PR’ is to set the voltage and current sensor gain constants, KV and KI, such that there will be ac- ceptable voltage levels on the CS5460A inputs when the power line voltage and current levels are at the maximum values of 250 V and 20 A. KV and KI are needed to determine the appropriate ratios of the voltage/current transformers and/or shunt resistor values to use in the front-end voltage/cur- rent sensor networks. For a sinewave, the largest RMS value that can be accurately measured (without over-driving the in- puts) will register ~0.7071 of the maximum DC in- put level. Since power signals are often not perfectly sinusoidal in real-world situations, and to provide for some over-range capability, the RMS Voltage Register and RMS Current Register is set to measure 0.6 when the RMS-values of the line-voltage and line-current levels are 250 V and 20 A. Therefore, when the RMS registers measure 0.6, the voltage level at the inputs will be 0.6 x 250 mV = 150 mV. The sensor gain con- stants, KV and KI, are determined by demanding that the voltage and current channel inputs should be 150 mV RMS when the power line voltage and current are at the maximum values of 250 V and 20 A. KV = 150 mV / 250 V = 0.0006 KI = 150 mV / 20 A = 0.0075 Ω These sensor gain constants are used to calculate what the input voltage levels will be on the CS5460A inputs when the line-voltage and line-current are 220 V and 15 A. These values are VVnom and VInom. VVnom =KV * 220 V = 132 mV VInom =KI * 15 A = 112.5 mV The pulse rate on EOUT will be at ‘PR’ pulses per second (Hz) when the RMS-levels of voltage/cur- rent inputs are at 250 mV. When the voltage/cur- rent inputs are set at VVnom and VInom, the pulse rate needs to be ‘IR’ = 100 pulses per second. IR will be some percentage of PR. The percentage is defined by the ratios of VVnom/250 mV and VInom/250 mV with the following formula: From this equation the value of ‘PR’ is shown as:. Therefore the Pulse-Rate Register is set to ~420.875 Hz, or 0x00349C. The above equation is valid when current channel is set to x10 gain. If current channel gain is set to x50, then the equation becomes: PulseRate IR PR V Vnom 250mV ------------------- V Inom 250mV ------------------- ⋅⋅ == PR IR V Vnom 250mV ------------------ V Inom 250mV ------------------ × -------------------------------------------- 100Hz 132mV 250mV ------------------ 112.5mV 250mV ----------------------- × ------------------------------------------------ == PR IR V Vnom 250mV ------------------ V Inom 50mV --------------- × ----------------------------------------- = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |