34 / 54 page ![]() HT49RU80/HT49CU80 Rev. 1.20 34 December 16, 2009 ¨ Transmit break If the TXBRK bit is set then break characters will be sent on the next transmission. Break character transmission consists of a start bit, followed by 13 ´ N ¢0¢ bits and stop bits, where N=1, 2, etc. If a break character is to be transmitted then the TXBRK bit must be first set by the application program, then cleared to generate the stop bits. Transmitting a break character will not generate a transmit inter- rupt. Note that a break condition length is at least 13 bits long. If the TXBRK bit is continually kept at a logic high level then the transmitter circuitry will transmit continuous break characters. After the ap- plication program has cleared the TXBRK bit, the transmitter will finish transmitting the last break character and subsequently send out one or two stop bits. The automatic logic highs at the end of the last break character will ensure that the start bit of the next frame is recognized. · UART receiver ¨ Introduction The UART is capable of receiving word lengths of ei- ther 8 or 9 bits. If the BNO bit is set, the word length will be set to 9 bits with the MSB being stored in the RX8 bit of the UCR1 register. At the receiver core lies the Receive Serial Shift Register, commonly known as the RSR. The data which is received on the RX external input pin, is sent to the data recovery block. The data recovery block operating speed is 16 times that of the baud rate, while the main receive serial shifter operates at the baud rate. After the RX pin is sampled for the stop bit, the received data in RSR is transferred to the receive data register, if the register is empty. The data which is received on the external RX input pin is sampled three times by a majority de- tect circuit to determine the logic level that has been placed onto the RX pin. It should be noted that the RSR register, unlike many other registers, is not di- rectly mapped into the Data Memory area and as such is not available to the application program for direct read/write operations. ¨ Receiving data When the UART receiver is receiving data, the data is serially shifted in on the external RX input pin, LSB first. In the read mode, the RXR register forms a buffer between the internal bus and the receiver shift register. The RXR register is a two byte deep FIFO data buffer, where two bytes can be held in the FIFO while a third byte can continue to be received. Note that the application program must ensure that the data is read from RXR before the third byte has been completely shifted in, otherwise this third byte will be discarded and an overrun error OERR will be subsequently indicated. The steps to initiate a data transfer can be summarized as follows: - Make the correct selection of BNO, PRT, PREN and STOPS bits to define the word length, parity type and number of stop bits. - Setup the BRG register to select the desired baud rate. - Set the RXEN bit to ensure that the RX pin is used as a UART receiver pin and not as an I/O pin. At this point the receiver will be enabled which will begin to look for a start bit. When a character is received the following se- quence of events will occur: - The RXIF bit in the USR register will be set when RXR register has data available, at least one more character can be read. - When the contents of the shift register have been transferred to the RXR register, then if the RIE bit is set, an interrupt will be generated. - If during reception, a frame error, noise error, par- ity error, or an overrun error has been detected, then the error flags can be set. The RXIF bit can be cleared using the following software sequence: 1. A USR register access 2. An RXR register read execution ¨ Receive break Any break character received by the UART will be managed as a framing error. The receiver will count and expect a certain number of bit times as speci- fied by the values programmed into the BNO and STOPS bits. If the break is much longer than 13 bit times, the reception will be considered as complete after the number of bit times specified by BNO and STOPS. The RXIF bit is set, FERR is set, zeros are loaded into the receive data register, interrupts are generated if appropriate and the RIDLE bit is set. If a long break signal has been detected and the re- ceiver has received a start bit, the data bits and the invalid stop bit, which sets the FERR flag, the re- ceiver must wait for a valid stop bit before looking for the next start bit. The receiver will not make the assumption that the break condition on the line is the next start bit. A break is regarded as a character that contains only zeros with the FERR flag set. The break character will be loaded into the buffer and no further data will be received until stop bits are re- ceived. It should be noted that the RIDLE read only flag will go high when the stop bits have not yet been received. The reception of a break character on the UART registers will result in the following: - The framing error flag, FERR, will be set. - The receive data register, RXR, will be cleared. - The OERR, NF, PERR, RIDLE or RXIF flags will possibly be set. ¨ Idle status When the receiver is reading data, which means it will be in between the detection of a start bit and the reading of a stop bit, the receiver status flag in the USR register, otherwise known as the RIDLE flag, will have a zero value. In between the reception of a stop bit and the detection of the next start bit, the RIDLE flag will have a high value, which indicates the receiver is in an idle condition. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |