Bypass Possibility
Parameter
Specification
Unit
Condition
Min.
Typ.
Max.
Power Supply
Voltage (V
CC)3
V
VSELECT Low
0.8
V
High Gain mode.
Select<0.8V, VPD/VREF=3V
VSELECT High
1.8
V
Low Gain mode.
Select>1.8V, VPD/VREF=0V
Power Down
0
10
μAGain Select<0.8V, VPD/VREF=0V, VCC=0V
Gain Select
VPD/VREF
VCC
Current
Comments
>1.8V
0V
3V
2.3mA
Recommended Bypass Mode
>1.8V
3V
3V
3.4mA
Alternative Bypass Mode