5 / 12 page ![]() MODEL: RZMS-U9 RZMS-U9 SPECIFICATIONS ES-7605 Rev.13 Page 5/12 http://www.m-system.co.jp/ RTD Input, Celsius RTD USABLE RANGE (°C) ACCURACY at < 0°C at ≥ 0°C Pt 100 (JIS ’97, IEC) -200 to +850 ±0.4°C ±[0.4°C + Measured Value × 0.1%] (±1.3°C at 850°C) Pt 200 -200 to +850 ±0.3°C ±[0.3°C + Measured Value × 0.17%] (±1.8°C at 850°C) Pt 300 -200 to +850 ±[0.4°C + Measured Value × 0.08%] (±0.24°C at -200°C) ±[0.4°C + Measured Value × 0.21%] (±2.2°C at 850°C) Pt 400 -200 to +850 ±[0.4°C + Measured Value × 0.11%] (±0.18°C at -200°C) ±[0.4°C + Measured Value × 0.21%] (±2.2°C at 850°C) Pt 500 -200 to +850 ±[0.4°C + Measured Value × 0.13%] (±0.14°C at -200°C) ±[0.4°C + Measured Value × 0.26%] (±2.6°C at 850°C) Pt 1000 -200 to +850 ±[0.4°C + Measured Value × 0.15%] (±0.10°C at -200°C) ±[0.4°C + Measured Value × 0.4%] (±3.8°C at 850°C) Pt 100 (JIS ’89) -200 to +660 ±0.4°C ±[0.4°C + Measured Value × 0.1%] (±1.1°C at 650°C) JPt 100 (JIS ’89) -200 to +510 ±0.4°C ±[0.4°C + Measured Value × 0.1%] (±0.91°C at 510°C) Pt 50Ω (JIS ’81) -200 to +649 ±0.5°C at < 160°C, ±[0.4°C + Measured Value × 0.1%] at ≥ 160°C (±1.049°C at 649°C) Ni 100 -80 to +260 ±0.3°C Ni 120 -80 to +260 ±0.3°C Ni 508.4Ω -50 to +280 ±[0.25°C + Measured Value × 0.06%] (±0.22°C at -50°C, ±0.42°C at 280°C) Ni-Fe 604 -200 to +200 ±0.9°C at -200°C, ±0.6°C at -150°C, ±0.5°C at ±100°C, ±0.7°C at 200°C Cu 10 @ 25°C -50 to +250 ±1.2°C (only after the field calibrations) RTD Input, Fahrenheit RTD USABLE RANGE (°F) ACCURACY at < 32°F at ≥ 32°F Pt 100 (JIS ’97, IEC) -328 to +1562 ±0.72°F ±[0.4°C + Measured Value × 0.1%] (±1.3°C at 850°C) Pt 200 -328 to +1562 ±0.54°F ±[0.3°C + Measured Value × 0.17%] (±1.8°C at 850°C) Pt 300 -328 to +1562 ±[0.72°F + Measured Value × 0.08%] (±0.44°F at -328°F) ±[0.4°C + Measured Value × 0.21%] (±2.2°C at 850°C) Pt 400 -328 to +1562 ±[0.72°F + Measured Value × 0.11%] (±0.33°F at -328°F) ±[0.4°C + Measured Value × 0.21%] (±2.2°C at 850°C) Pt 500 -328 to +1562 ±[0.72°F + Measured Value × 0.13%] (±0.26°F at -328°F) ±[0.4°C + Measured Value × 0.26%] (±2.6°C at 850°C) Pt 1000 -328 to +1562 ±[0.72°F + Measured Value × 0.15%] (±0.18°F at -328°F) ±[0.4°C + Measured Value × 0.4%] (±3.8°C at 850°C) Pt 100 (JIS ’89) -328 to +1220 ±0.72°F ±[0.4°C + Measured Value × 0.1%] (±1.1°C at 650°C) JPt 100 (JIS ’89) -328 to +950 ±0.72°F ±[0.4°C + Measured Value × 0.1%] (±0.91°C at 510°C) Pt 50Ω (JIS ’81) -328 to +1200 ±0.9°F at < 320°F, ±[0.72°F + Measured Value × 0.1%] at ≥ 320°F (±1.888°F at 1200°F) Ni 100 -112 to +500 ±0.54°F Ni 120 -112 to +500 ±0.54°F Ni 508.4Ω -58 to +536 ±[0.45°F + Measured Value × 0.06%] (±0.40°F at -58°F, ±0.76°F at 536°F) Ni-Fe 604 -328 to +392 ±1.62°F at -328°F, ±1.08°F at -238°F, ±0.9°F at ±212°F, ±1.26°F at 392°F Cu 10 @ 25°C -58 to +482 ±2.16°F (only after the field calibrations) Note 1: The lower the temperature range, the better the accuracy is for Pt 300, Pt 400, Pt 500, Pt 1000 and Ni 508.4Ω. ‘Measured Value’ in the equations is not an absolute value. Include the minus sign when calculating accuracies. Note 2: For Cu 10 @ 25°C, be sure to perform the field calibrations of wire imbalance and zero/span by using the PC Configurator Software. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |