| Electronic Components Datasheet Search |
|
AS3689 Datasheet(PDF) 28 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS3689 Datasheet(HTML) 28 Page - ams-OSRAM AG |
|
28 / 72 page ![]() AS3689 austriami crosyst ems Datasheet, Confidential www.austriamicrosystems.com (mlg, ptr) Revision 1.0.2 / 20070115 26 - 70 DCDC Control 2 Addr: 22h This register controls the Step Up DC/DC Converter and low-voltage current sinks CURR3x. Bit Bit Name Default Access Description 0 step_up_res 0 R/W Gain selection for Step Up DC/DC Converter. 0 = Select 0 if Step Up DC/DC Converter is used with current feedback (CURR1, CURR2) or if DCDC_FB is used with current feedback only – only R1, C1 connected 1 = Select 1 if DCDC_FB is used with external resistor divider (2 resistors). 1 skip_fast 0 R/W Step Up DC/DC Converter output voltage at low loads, when pulse skipping is active. 0 = Accurate output voltage, more ripple. 1 = Elevated output voltage, less ripple. 2 stepup_prot 1 R/W Step Up DC/DC Converter protection. 0 = No overvoltage protection. 1 = Overvoltage protection on pin DCDC_FB enabled voltage limitation =1.25V on DCDC_FB 3 stepup_lowcur 1 R/W Step Up DC/DC Converter coil current limit. 0 = .Normal current limit 1 = Current limit reduced by approx. 33% 4 curr1_prot_on 0 R/W 0 = No overvoltage protection 1 = Pull down current on CURR1 switched on, if voltage on CURR1 exceeds 13.75V, and step_up_on=1 5 curr2_prot_on 0 R/W 0 = No overvoltage protection 1 = Pull down current on CURR2 switched on, if voltage exceeds on CURR2 13.75V, and step_up_on=1 6 curr6_prot_on 0 R/W 0 = No overvoltage protection 1 = Pull down current on CURR6 switched on, if voltage on CURR6 exceeds 13.75V, and step_up_on=1 7 step_up_fb_auto 0 R/W 0 = step_up_fb select the feedback of the DCDC converter 1 = The feedback is automatically chosen within the current sinks CURR1and CURR2 (never DCDC_FB). Only those are used for this selection, which are enabled (currX_mode must not be 00) and not connected to the charge pump (currX_on_cp must be 0). 7.4.2 Current Sinks CURR30, CURR31, CURR32, CURR33 These current sinks have a preview and strobe setting. The preview and strobe can be controlled by software (register bit) or GPIO can be programmed to enter preview mode (polarity programmable) and GPI can be programmed to enter strobe mode (polarity programmable). In strobe mode, a timeout timer protects the flash leds with a settable timeout of 100ms to 1600ms. This timer has the following modes: Flash time defined by timeout timer (Ts) independent of strobe signal (Mode 1) Flash time limited to timeout or end of strobe pulse (Mode 2) Flash time as timeout timer setting independent of strobe pulse length (Mode 3) Table 12 – High Current Sinks CURR30,31,32,33 Parameters Symbol Parameter Min Typ Max Unit Note IBIT5 Current sink if Bit5 = 1 19.2 IBIT4 Current sink if Bit4 = 1 9.6 For V(CURRx) > 0.2 / 0.4V |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |