AS3689 Datasheet(PDF) 19 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS3689 Datasheet(HTML) 19 Page - ams-OSRAM AG |
|
19 / 72 page ![]() AS3689 austriami crosyst ems Datasheet, Confidential www.austriamicrosystems.com (mlg, ptr) Revision 1.0.2 / 20070115 17 - 70 Table 9 – Charge Pump Characteristics Symbol Parameter Min Typ Max Unit Note ICPOUT_Pulsed Output Current Pulsed 0.0 400 mA 300ms pulse width, 10% duty cycle max. ICPOUT Output Current Continuous 0.0 350 mA Depending on PCB layout VCPOUTmax Output Voltage 5.5 V Internally limited, Including output ripple η Efficiency 60 90 % Including current sink loss; ICPOUT < 400mA. ICP1_1.5 7 1:1.5 Mode ICP1_2 Power Consumption without Load fclk = 1 MHz 8 1:2 Mode Rcp1_1 0.7 1.5 1:1 Mode; VBAT >= 3.5V Rcp1_1.5 1.8 3.0 1:1.5 Mode; VBAT >= 3.3V Rcp1_2 Effective Charge Pump Output Resistance (Open Loop, fclk = 1MHz) 2 3.5 1:1.2 Mode; VBAT >= 3.1V fclk Accuracy Accuracy of Clock Frequency -10 10 % currlv_switch RGB1:RGB3, CURR41:CURR42 and CURR51:CURR52 minumum voltage 0.2 V currhv_switch CURR1, CURR2, CURR6 minumum voltage 0.45 V CURR30:CURR33 minumum voltage 0-160mA range 0.2 V curr3x_switch CURR30:CURR33 minumum voltage >160mA range 0.4 V If the voltage drops below this threshold, the charge pump will use the next available mode (1:1 -> 1:1.5 or 1:1.5 -> 1:2) 240 µsec cp_start_debounce=0 tdeb CP automatic up- switching debounce time 2000 µsec After switching on CP (cp _on set to 1), if cp_start_debounce=1 7.3.1 Charge Pump Mode Switching If automatic mode switching is enabled (cp_mode_switching = 00 or cp_mode_switching = 01) the charge pump monitors the current sinks, which are connected via a led to the output CP_OUT. To identify these current sources (sinks), the registers cp_mode_switch1 and cp_mode_switch2 (register bits curr30_on_cp … curr33_on_cp, rgb1_on_cp … rgb3_on_cp, curr1_on_cp, curr2_on_cp, curr41_on_cp … curr43_on_cp) should be setup before starting the charge pump (cp _on = 1). If any of the voltage on these current sources drops below the threshold (currlv_switch, currhv_switch, curr3x_switch), the next higher mode is selected after the debounce time. To avoid switching into 1:2 mode (battery current = 2 times output current), set cp_mode_switching = 10. If the currX_on_cp=0 and the according current sink is connected to the chargepump, the current sink will be functional, but there is no up switching of the chargepump, if the voltage compliance is too low for the current sink to supply the specified current. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |