AM79C970AVCW Datasheet(PDF) 89 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C970AVCW Datasheet(HTML) 89 Page - Advanced Micro Devices |
|
89 / 219 page ![]() P R E L I M I N A R Y AMD 89 Am79C970A Table 10. GPSI Pin Configuration PCnet-PCI II PCnet-PCI II PCnet-PCI II Controller C-LANCE Controller Controller Expansion GPSI Function GPSI I/O Type GPSI Pin GPSI Pin Pin Number ROM Pin Collision I CLSN CLSN 81 ERD3 Receive Clock I RCLK RXCLK 85 ERD1 Receive Data I RX RXDAT 86 ERD0 Receive Enable I RENA RXEN 83 ERD2 Transmit Clock I TCLK TXCLK 80 ERD4 Transmit Data O TX TXDAT 75 ERD7 Transmit Enable O TENA TXEN 77 ERD6 Note that the XTAL1 input must always be driven with a clock source, even if GPSI mode is to be used. It is not necessary for the XTAL1 clock to meet the normal fre- quency and stability requirements in this case. Any fre- quency between 8 MHz and 20 MHz is acceptable. However, voltage drive requirements do not change. When GPSI mode is used, XTAL1 must be driven for several reasons: s The default H_RESET configuration for the PCnet- PCI II controller is AUI port selected and until GPSI mode is selected, the XTAL1 clock is needed for some internal operations (namely, RESET). s The XTAL1 clock drives the EEPROM read opera- tion, regardless of the network mode selected. s The XTAL1 clock determines the length the internal S_RESET caused by the read of the Reset register, regardless of the network mode. Note that if a clock slower than 20 MHz is provided at the XTAL1 input, the time needed for EEPROM read and the internal S_RESET will increase. External Address Detection Interface The External Address Detection Interface (EADI) is pro- vided to allow external address filtering. It is selected by setting the EADISEL bit in BCR2 to ONE. This feature is typically utilized for terminal servers, bridges and/or router products. The EADI interface can be used in con- junction with external logic to capture the packet desti- nation address from the serial bit stream as it arrives at the PCnet-PCI II controller, compare the captured ad- dress with a table of stored addresses or identifiers, and then determine whether or not the PCnet-PCI II control- ler should accept the packet. The EADI interface outputs are delivered directly from the NRZ decoded data and clock recovered by the Manchester decoder or input into the GPSI port. This al- lows the external address detection to be performed in parallel with frame reception and address comparison in the MAC Station Address Detection (SAD) block of the PCnet-PCI II controller. SRDCLK is provided to allow clocking of the receive bit stream into the external address detection logic. Note that when the 10BASE-T port is selected, transitions on SRDCLK will only occur during receive activity. When the AUI or GPSI port is selected, transitions on SRDCLK will occur during both transmit and receive activity. Once a received frame commences and data and clock are available from the decoder, the EADI logic will monitor the alternating (1,0) preamble pattern until the two ONEs of the Start Frame Delimiter (SFD, 10101011 bit pattern) are detected, at which point the SFBD output will be driven HIGH. The SFBD signal will initially be LOW. The assertion of SFBD is a signal to the external address detection logic that the SFD has been detected and that subsequent SRDCLK cycles will deliver packet data to the external logic. Therefore, when SFBD is asserted, the external address matching logic should begin de-serialization of the SRD data and send the resulting destination ad- dress to a Content Addressable Memory (CAM) or other address detection device. In order to reduce the amount of logic external to the PCnet-PCI II controller for multi- ple address decoding systems, the SFBD signal will toggle at each new byte boundary within the packet, subsequent to the SFD. This eliminates the need for ex- ternally supplying byte framing logic. SRD is the decoded NRZ data from the network. This signal can be used for external address detection. Note that when the 10BASE-T port is selected, transitions on SRD will only occur during receive activity. When the AUI or GPSI port is selected, transitions on SRD will oc- cur during both transmit and receive activity. The EAR pin should be driven LOW by the external ad- dress comparison logic to reject a frame. If an address match is detected by comparison with either the Physical Address or Logical Address Filter registers contained within the PCnet-PCI II controller or the frame is of the type “Broadcast”, then the frame will be accepted regardless of the condition of EAR. When |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |